Answer: An easy way is by using an intersystem bonding termination. This is for lightning protection. Allows for connections. To view this site, you must enable JavaScript or upgrade to a JavaScript-capable browser.
Bonding for Other Systems. Includes mounting hole and weather-resistant PVC Cover. It provides a dependable method for grounding and bonding for electrical systems.
Typical applications include communications, solar, cable, and transmission lines. It has a compact design and includes a U. Blackburn Aluminum ground bar is for convenient and reliable grounding of communications, satellite, CATV and utility services. V stabilized cover that can be painted. The IBT is only for bonding communications systems and cannot be used for bonding anything else other than communications systems. Fill Your Cart With Color Today!
AWG bonding conductors and one Class I copper lightning conductor. Product Information. INLINE INTERSYSTEM BONDING BRIDGE. The neutral bar is connected to the main service disconnect enclosure, has main bonding jumper which connects to the equipment grounding bus bar.
From controlled environments of a data center to the demanding continuity of the power grid. Hubbell serves the needs of customers in a variety of market applications. A decorative cover is included. See the major markets and building types below.
There are no ground rods at this site. We usually attach the intersystem bond to the wire going to the ground rod. Would this be considered electrically connected as required by 250.
For structures supplied by a feeder, you must provide an external intersystem bonding terminal at the metering equipment enclosure and disconnecting means. Our POCO allows this bar to be connected to the socket. The resulting termination must: Be accessible for connection and inspection.
Consist of a set of terminals with the capacity for connecting at least three intersystem bonding conductors. Basically the same thing as using a bonding bar. I though an electrician was crazy when he said some cable guy put a clip on an outdoor panel cover when there was a nice bonding bar mounted to the ground conduit.
Intersystem grounding bridge, has termination points, one more than required by the NEC. Ultrafast transient absorption spectroscopy is applied to diiodo-BODIPY in the presence of pyridine-based halogen bonding solvent molecules to determine the rate constants for intersystem crossing. Wide Selection of Connectors from Hubbell Wiring Device-Kellems. An intersystem bonding termination shall consist of a set of terminals with the capacity for connection of not less than _____ intersystem bonding conductors. We find that halogen bonding facilitates the formation of the triplet state by increasing the intersystem crossing rate constant of diiodo-BODIPY.
If the intersystem bonding termination for a communications system is provided through a set of terminals securely mounted to the meter or service equipment enclosure, the terminals have to be _____. Great Customer Service. Used in residential and commercial applications to ground up to four (4) systems to a single location. Available in die-cast zinc or copper alloy. Connects directly to the grounding electrode with a lay-in style lug.
Integrated mounting holes provide quick, easy and compact installation. Used as an Intersystem bonding means by utilizing 4-terminal points for connecting communication systems to the same electrical grounding electrode, rod or rebar. Lay-in style connection and good for up to four auxiliary ground wires.
You mount the bar right on the outside of the house near the electrical service. Bay Is Here For You with Money Back Guarantee and Easy Return.