Aluminum Ground Bar from Blackburn is an important accessory in your home or business electrical load center. Offers long lasting durability. Click Here to try it today! A bonding bar near the service equipment enclosure or raceway for service conductors.
The bonding bar shall be connected with minimum AWG copper conductor (s) to an equipment grounding conductor (s) in the service equipment enclosure, meter enclosure, or exposed non-flexible metallic raceway. The neutral bar is connected to the main service disconnect enclosure, has main bonding jumper which connects to the equipment grounding bus bar. Electrician Talk - Professional Electrical. Bonding for Other Systems.
Wound a bus bar connected to the exterior of a meter socket (for bonding intersystem grounding conductors) with self tapped screws and no bonding wire be a code violation? Our POCO allows this bar to be connected to the socket. Would this be considered electrically connected as required by 250. Choose Favorites List.
Zoom In Zoom Out Enlarge. A decorative cover is included. Hubbell serves the needs of customers in a variety of market applications.
You mount the bar right on the outside of the house near the electrical service. A Ufer is a grounding connection to the metal rebar in your foundation some house have instead of ground rods. GROUNDING AND BONDING GROUND BARS AND. AWG bonding conductors and one Class I copper.
Removable plastic cover is included to provide long lasting outdoor life. An intersystem bonding termination for connecting intersystem bonding conductors required for other systems shall be provided external to enclosures at the service equipment or metering equipment enclosure and at the disconnecting means for any additional buildings or structures. View Customer Accounts ) We have updated our data protection policies based on the new GDPR act. The intersystem bonding termination device shall not interfere with opening a service or metering equipment enclosure.
The bonding bar must be connected to the grounding-electrode conductor by a minimum AWG copper conductor. The electrical contractor is responsible for the installation of the intersystem bonding termination, and the communications contractor is responsible for the connection of the communications bonding conductors to the terminal bar. Rack Isolation Pads. The yellow arrow shows the bonding bar used to accomplish this. So in the main panel only (like this one) the grounding and neutral conductors can be on the same bus terminal if desired.
If the panel is fed by a three wire feeder has a separate grounding bar (no neutrals on it) then it must be bonded to the neutral bar with a bonding jumper. I understand the importance of connecting my feedline shields to the service entrance groun but have a bit of a predicament when it comes to routing of coax from the service entrance to my shack. Used in residential and commercial applications to ground up to four (4) systems to a single location. Lay-in style connection and good for up to four auxiliary ground wires. Available in die-cast zinc or copper alloy.
It has impact-resistant polymer construction. It measures 4-Inch x 2. Register or with your Gexpro Account for price or to order. Intersystem bonding termination bar is cULus listed.
For assistance, contact us. Morris Products Inc. A DiversiTech Company.